NHP Power System LLP
NHP Power System LLP
Hadapsar, Pune, Maharashtra
GST No. 27AAKFN4046M1ZU
TrustSEAL Verified
Call 0804603509977% Response Rate
SEND EMAIL

Switch Mode Power Supply SMPS - PES Series

 

 

The PES series is one of the latest entrants from NHP Power system in its line of state of the art power supplies made from UL94 V-0 approved raw material. It functions from a wide AC input range and at the same time accepts DC input voltage. Its main features are low no-load power consumption, high efficiency and high reliability. These power supply offer excellent EMC performance and meet international standards and are widely used in areas of industrial automation, street light control, electricity, security, telecommunications, smart home, etc.

 

 

NHP-PES-24 (SMPS 12V 2A) AC/DC Switch Mode Power Supply

NHP-PES-24 (SMPS 12V 2A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 12V 2A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 12V 2A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 12V 2A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 350 / PieceGet Latest Price
Product Brochure

Product Details:

Output Voltage12V
Voltage30 V
Current25A
Usage/ApplicationIndustrial Automation
DesignSmps
Display TypeDigital
Output Current2A
Country of OriginMade in India

Salient Features:
•90 - 300V Universal AC or wide 130 - 400V DC Input
•Operating ambient temperature range: -40Deg C to +85Deg C 
•High I/O isolation test voltage up to 3000VAC
•Regulated output, low ripple & noise
•Output short circuit, over-current protection 
•High efficiency, high reliability 


Input Specifications:

Input Voltage

90 to 300V AC

Input Voltage Frequency

40Hz to 70Hz

Input Current

 0.25A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 35A

Leakage current

<2 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.02%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On



PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested

NHP-PES-24 (SMPS 5V 3A) AC/DC Switch Mode Power Supply

NHP-PES-24 (SMPS 5V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 5V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 5V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 5V 3A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 350 / PieceGet Latest Price
Product Brochure

Product Details:

Output Voltage5V
Voltage30 V
Usage/ApplicationIndustrial Automation
Current30A
DesignSmps
Display TypeDigital
Output Current3A
Country of OriginMade in India

Salient Features:
•90 - 300V Universal AC or wide 130 - 400V DC Input
•Operating ambient temperature range: -40Deg C to +85Deg C 
•High I/O isolation test voltage up to 3000VAC
•Regulated output, low ripple & noise
•Output short circuit, over-current protection 
•High efficiency, high reliability 


Input Specifications:

Input Voltage

90 to 300V AC

Input Voltage Frequency

40Hz to 70Hz

Input Current

 0.25A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 35A

Leakage current

<2 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.02%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On



PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested

NHP-PES-24 (SMPS 24V 1A) AC/DC Switch Mode Power Supply

NHP-PES-24 (SMPS 24V 1A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 24V 1A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 24V 1A) AC/DC Switch Mode Power Supply
  • NHP-PES-24 (SMPS 24V 1A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 350 / PieceGet Latest Price
Product Brochure

Product Details:

Voltage24 V
Output Voltage5V
Current25A
Usage/ApplicationIndustrial Automation
DesignSmps
Display TypeDigital
Output Current1A
Country of OriginMade in India

Salient features:
•90 - 300v universal ac or wide 130 - 400v dc input
•operating ambient temperature range: -40deg c to +85deg c 
•high i/o isolation test voltage up to 3000vac
•regulated output, low ripple & noise
•output short circuit, over-current protection 
•high efficiency, high reliability 


input specifications:

input voltage

90 to 300v ac

input voltage frequency

40hz to 70hz

input current

 0. 25a typical at 230v ac

input inrush current

limited by ntc thermistor to 35a

leakage current

<2 ma at 230v ac

output specifications:

output voltage accuracy

at full load range ±1 %

line regulation

<1%

load regulation

<1%

ripple and noise

150 mv p-p

temperature coefficient

±0. 02%/deg c

hold-up time 230v ac

20ms

protections:

input under voltage

cut-off level 140v ac; turn on voltage 160v ac

input over voltage

310v ac units shuts off if voltage goes above this value and automatic restart when input is less than 275v ac

output short circuit and overload

continuously protected

general specifications:

operating temperature

-20 to 85 deg c

storage temperature

-20 to 85 deg c

operating humidity

20 to 95%rh

storage humidity

10 to 95%rh

vibration

10-500 hz 2g 10 min/cycle 60 mins each along xyz axis

indication

mains on



please refer to datasheet for further details.

Request
Callback
Yes! I am interested

NHP-PES-35 (SMPS 24V 1.5A) AC/DC Switch Mode Power Supply

NHP-PES-35 (SMPS 24V 1.5A) AC/DC Switch Mode Power Supply
  • NHP-PES-35 (SMPS 24V 1.5A) AC/DC Switch Mode Power Supply
  • NHP-PES-35 (SMPS 24V 1.5A) AC/DC Switch Mode Power Supply
  • NHP-PES-35 (SMPS 24V 1.5A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 450 / PieceGet Latest Price
Product Brochure

Product Details:

Voltage40 V
Output Voltage24V
Usage/ApplicationIndustrial Automation
Current25A
DesignSmps
Output Current1.5A
Country of OriginMade in India

Salient features:

•input 170v to 270v ac operating range 
•operating temperature -20 to 85 deg c
•low standby power consumption and high efficiency  
•input over and under voltage protections
•led indicator for power on
•output short circuit, over-load, over-voltage protection
•leading supplier for major oe manufactures for 25 years
•all our products come with a 1-year warranty against all manufacturing defects


input specifications:

input voltage

170 to 270v ac

input voltage frequency

47hz to 63hz

input current

 1a typical at 230v ac

input inrush current

limited by ntc thermistor to 35a

leakage current

<0. 75 ma at 230v ac

output specifications:

output voltage accuracy

at full load range ±1 %

line regulation

<1%

load regulation

<1%

ripple and noise

150 mv p-p

temperature coefficient

±0. 03%/deg c

hold-up time 230v ac

20ms

protections:

input under voltage

cut-off level 140v ac; turn on voltage 160v ac

input over voltage

310v ac units shuts off if voltage goes above this value and automatic restart when input is less than 275v ac

output short circuit and overload

continuously protected

general specifications:

operating temperature

-20 to 85 deg c

storage temperature

-20 to 85 deg c

operating humidity

20 to 95%rh

storage humidity

10 to 95%rh

vibration

10-500 hz 2g 10 min/cycle 60 mins each along xyz axis

indication

mains on


please refer to datasheet for further details.

Request
Callback
Yes! I am interested

NHP-PES-35 (SMPS 12V 3A) AC/DC Switch Mode Power Supply

NHP-PES-35 (SMPS 12V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-35 (SMPS 12V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-35 (SMPS 12V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-35 (SMPS 12V 3A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 450 / PieceGet Latest Price
Product Brochure

Product Details:

Output Voltage12V
Voltage30 V
Current30A
Usage/ApplicationIndustrial Automation
DesignSmps
Output Current3A
Country of OriginMade in India

Salient Features:

•Input 170V to 270V AC operating range 
•Operating Temperature -20 to 85 Deg C
•Low Standby Power Consumption and High Efficiency  
•Input over and under voltage protections
•LED indicator for power on
•Output short circuit, over-load, over-voltage protection
•Leading supplier for major OE manufactures for 25 years
•All our products come with a 1-year warranty against all manufacturing defects


Input Specifications:

Input Voltage

170 to 270V AC

Input Voltage Frequency

47Hz to 63Hz

Input Current

 1A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 35A

Leakage current

<0.75 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.03%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On


PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested

NHP-PES-100 (SMPS 24V 4A) AC/DC Switch Mode Power Supply

NHP-PES-100 (SMPS 24V 4A) AC/DC Switch Mode Power Supply
  • NHP-PES-100 (SMPS 24V 4A) AC/DC Switch Mode Power Supply
  • NHP-PES-100 (SMPS 24V 4A) AC/DC Switch Mode Power Supply
  • NHP-PES-100 (SMPS 24V 4A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 600 / PieceGet Latest Price
Product Brochure

Product Details:

Output Voltage24V
Usage/ApplicationIndustrial Automation
DesignSmps
Display TypeDigital
WarrantyNo
Output Current4A
Country of OriginMade in India

Salient Features:

•Input 170V to 270V AC operating range 
•Operating Temperature -20 to 85 Deg C
•Low Standby Power Consumption and High Efficiency  
•Input over and under voltage protections
•LED indicator for power on
•Output short circuit, over-load, over-voltage protection
•Leading supplier for major OE manufactures for 25 years
•All our products come with a 1-year warranty against all manufacturing defects


Input Specifications:

Input Voltage

170 to 270V AC

Input Voltage Frequency

47Hz to 63Hz

Input Current

 1A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 35A

Leakage current

<0.75 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.03%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On


PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested

NHP-PES-72 (SMPS 24V 3A) AC/DC Switch Mode Power Supply

NHP-PES-72 (SMPS 24V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 24V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 24V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 24V 3A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 24V 3A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 550 / PieceGet Latest Price
Product Brochure

Product Details:

Voltage30 V
Output Voltage24V
Current25A
Usage/ApplicationIndustrial Automation
DesignSmps
Output Current3A
Country of OriginMade in India

Salient Features:

•Input 170V to 270V AC operating range 
•Operating Temperature -20 to 85 Deg C
•Low Standby Power Consumption and High Efficiency  
•Input over and under voltage protections
•LED indicator for power on
•Output short circuit, over-load, over-voltage protection
•Leading supplier for major OE manufactures for 25 years
•All our products come with a 1-year warranty against all manufacturing defects


Input Specifications:

Input Voltage

170 to 270V AC

Input Voltage Frequency

47Hz to 63Hz

Input Current

 1A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 35A

Leakage current

<0.75 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.03%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On


PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested

NHP-PES-72 (SMPS 12V 5A) AC/DC Switch Mode Power Supply

NHP-PES-72 (SMPS 12V 5A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 12V 5A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 12V 5A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 12V 5A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 550 / PieceGet Latest Price
Product Brochure

Product Details:

Output Voltage12V
Usage/ApplicationIndustrial Automation
DesignSmps
Display TypeDigital
Output Current5A
WarrantyNo
Country of OriginMade in India

Salient features:

•input 170v to 270v ac operating range 
•operating temperature -20 to 85 deg c
•low standby power consumption and high efficiency  
•input over and under voltage protections
•led indicator for power on
•output short circuit, over-load, over-voltage protection
•leading supplier for major oe manufactures for 25 years
•all our products come with a 1-year warranty against all manufacturing defects


input specifications:

input voltage

170 to 270v ac

input voltage frequency

47hz to 63hz

input current

 1a typical at 230v ac

input inrush current

limited by ntc thermistor to 35a

leakage current

<0. 75 ma at 230v ac

output specifications:

output voltage accuracy

at full load range ±1 %

line regulation

<1%

load regulation

<1%

ripple and noise

150 mv p-p

temperature coefficient

±0. 03%/deg c

hold-up time 230v ac

20ms

protections:

input under voltage

cut-off level 140v ac; turn on voltage 160v ac

input over voltage

310v ac units shuts off if voltage goes above this value and automatic restart when input is less than 275v ac

output short circuit and overload

continuously protected

general specifications:

operating temperature

-20 to 85 deg c

storage temperature

-20 to 85 deg c

operating humidity

20 to 95%rh

storage humidity

10 to 95%rh

vibration

10-500 hz 2g 10 min/cycle 60 mins each along xyz axis

indication

mains on


please refer to datasheet for further details.

Request
Callback
Yes! I am interested

NHP-PES-125 (SMPS 24V 5A) AC/DC Switch Mode Power Supply

NHP-PES-125 (SMPS 24V 5A) AC/DC Switch Mode Power Supply
  • NHP-PES-125 (SMPS 24V 5A) AC/DC Switch Mode Power Supply
  • NHP-PES-125 (SMPS 24V 5A) AC/DC Switch Mode Power Supply
  • NHP-PES-125 (SMPS 24V 5A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 650 / PieceGet Latest Price
Product Brochure

Product Details:

Output Voltage24V
Voltage24 V
Usage/ApplicationIndustrial Automation
Current25A
BrandAPC
DesignSmps
Display TypeDigital
Output Current5A
Country of OriginMade in India

Salient features:

•input 170v to 270v ac operating range 
•operating temperature -20 to 85 deg c
•low standby power consumption and high efficiency  
•input over and under voltage protections
•led indicator for power on
•output short circuit, over-load, over-voltage protection
•leading supplier for major oe manufactures for 25 years
•all our products come with a 1-year warranty against all manufacturing defects


input specifications:

input voltage

170 to 270v ac

input voltage frequency

47hz to 63hz

input current

 1a typical at 230v ac

input inrush current

limited by ntc thermistor to 35a

leakage current

<0. 75 ma at 230v ac

output specifications:

output voltage accuracy

at full load range ±1 %

line regulation

<1%

load regulation

<1%

ripple and noise

150 mv p-p

temperature coefficient

±0. 03%/deg c

hold-up time 230v ac

20ms

protections:

input under voltage

cut-off level 140v ac; turn on voltage 160v ac

input over voltage

310v ac units shuts off if voltage goes above this value and automatic restart when input is less than 275v ac

output short circuit and overload

continuously protected

general specifications:

operating temperature

-20 to 85 deg c

storage temperature

-20 to 85 deg c

operating humidity

20 to 95%rh

storage humidity

10 to 95%rh

vibration

10-500 hz 2g 10 min/cycle 60 mins each along xyz axis

indication

mains on


please refer to datasheet for further details.

Request
Callback
Yes! I am interested

NHP-PES-72 (SMPS 5V 6.5A) AC/DC Switch Mode Power Supply

NHP-PES-72 (SMPS 5V 6.5A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 5V 6.5A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 5V 6.5A) AC/DC Switch Mode Power Supply
  • NHP-PES-72 (SMPS 5V 6.5A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 550 / PieceGet Latest Price
Product Brochure

Product Details:

Voltage24 V
Output Voltage5V
Current25A
Usage/ApplicationIndustrial Automation
DesignSmps
Output Current6.5A
Country of OriginMade in India

Salient Features:

•Input 170V to 270V AC operating range 
•Operating Temperature -20 to 85 Deg C
•Low Standby Power Consumption and High Efficiency  
•Input over and under voltage protections
•LED indicator for power on
•Output short circuit, over-load, over-voltage protection
•Leading supplier for major OE manufactures for 25 years
•All our products come with a 1-year warranty against all manufacturing defects


Input Specifications:

Input Voltage

170 to 270V AC

Input Voltage Frequency

47Hz to 63Hz

Input Current

 1A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 35A

Leakage current

<0.75 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.03%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On


PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested
X

Explore More Products

View All Products




Reach Us
Fatima Mulla (Manager)
NHP Power System LLP
NHP House, Plot No. 8, Ramtekdi Industrial Estate, TP Scheme 2
Hadapsar, Pune - 411013, Maharashtra, India
Get Directions


Call Us


Send E-mail