We are a leading Manufacturer of nhp-les-350 (smps 24v 15a) ac/dc switch mode power supply, nhp-les-350 (smps 36v 10a) ac/dc switch mode power supply and nhp-les-350 (smps 15v 23a) ac/dc switch mode power supply from Pune, India.

NHP-LES-350 (SMPS 24V 15A) AC/DC Switch Mode Power Supply

NHP-LES-350 (SMPS 24V 15A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 24V 15A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 24V 15A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 24V 15A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 1,500 / PieceGet Latest Price
Product Brochure

Product Details:

Voltage24 V
Output Voltage24V
Usage/ApplicationIndustrial Automation
DesignSmps
Display TypeDigital
Output TypeSingle
Output Current15A
Country of OriginMade in India

Salient Features:

•Input 170V to 270V AC operating range 
•Operating Temperature -20 to 85 Deg C
•Low Standby Power Consumption and High Efficiency  
•Input over and under voltage protections
•LED indicator for power on
•Output short circuit, over-load, over-voltage protection
•Leading supplier for major OE manufactures for 25 years
•All our products come with a 1-year warranty against all manufacturing defects


Input Specifications:

Input Voltage

170 to 270V AC

Input Voltage Frequency

47Hz to 63Hz

Input Current

3A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 60A

Leakage current

<3.5 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.03%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On


PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested

NHP-LES-350 (SMPS 36V 10A) AC/DC Switch Mode Power Supply

NHP-LES-350 (SMPS 36V 10A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 36V 10A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 36V 10A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 36V 10A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 1,500 / PieceGet Latest Price
Product Brochure

Product Details:

Voltage30 V
Output Voltage5V
Current25A
Usage/ApplicationIndustrial Automation
DesignSmps
Cooling TypeAir Cooled
Output Current10A
Country of OriginMade in India

Salient Features:

•Input 170V to 270V AC operating range 
•Operating Temperature -20 to 85 Deg C
•Low Standby Power Consumption and High Efficiency  
•Input over and under voltage protections
•LED indicator for power on
•Output short circuit, over-load, over-voltage protection
•Leading supplier for major OE manufactures for 25 years
•All our products come with a 1-year warranty against all manufacturing defects


Input Specifications:

Input Voltage

170 to 270V AC

Input Voltage Frequency

47Hz to 63Hz

Input Current

3A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 60A

Leakage current

<3.5 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.03%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On


PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested

NHP-LES-350 (SMPS 15V 23A) AC/DC Switch Mode Power Supply

NHP-LES-350 (SMPS 15V 23A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 15V 23A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 15V 23A) AC/DC Switch Mode Power Supply
  • NHP-LES-350 (SMPS 15V 23A) AC/DC Switch Mode Power Supply
Get Best Quote
Approx. Price: Rs 1,500 / PieceGet Latest Price
Product Brochure

Product Details:

Output Voltage12V DC
Usage/ApplicationIndustrial Automation
DesignSmps
Display TypeDigital
Output Current23A
Output-Voltage15V
Country of OriginMade in India

Salient Features:

•Input 170V to 270V AC operating range 
•Operating Temperature -20 to 85 Deg C
•Low Standby Power Consumption and High Efficiency  
•Input over and under voltage protections
•LED indicator for power on
•Output short circuit, over-load, over-voltage protection
•Leading supplier for major OE manufactures for 25 years
•All our products come with a 1-year warranty against all manufacturing defects


Input Specifications:

Input Voltage

170 to 270V AC

Input Voltage Frequency

47Hz to 63Hz

Input Current

3A Typical at 230V AC

Input Inrush Current

Limited by NTC Thermistor to 60A

Leakage current

<3.5 mA at 230V AC

Output Specifications:

Output voltage Accuracy

At full load range ±1 %

Line Regulation

<1%

Load Regulation

<1%

Ripple and noise

150 mv p-p

Temperature Coefficient

±0.03%/Deg C

Hold-up Time 230V AC

20ms

Protections:

Input under voltage

Cut-off level 140V AC; Turn on voltage 160V AC

Input over voltage

310V AC units shuts off if voltage goes above this value and automatic restart when input is less than 275V AC

Output short circuit and overload

Continuously Protected

General Specifications:

Operating Temperature

-20 to 85 Deg C

Storage Temperature

-20 to 85 Deg C

Operating Humidity

20 to 95%RH

Storage Humidity

10 to 95%RH

Vibration

10-500 Hz 2G 10 min/cycle 60 mins each along XYZ axis

Indication

Mains On


PLEASE REFER TO DATASHEET FOR FURTHER DETAILS.

Request
Callback
Yes! I am interested
X

Explore More Products

View All Products




Reach Us
Fatima Mulla (Manager)
NHP Power System LLP
NHP House, Plot No. 8, Ramtekdi Industrial Estate, TP Scheme 2
Hadapsar, Pune - 411013, Maharashtra, India
Get Directions


Call Us


Send E-mail